iE 250 Marine application SW (Protection & Paralleling)

iE 250 Marine application SW (Protection & Paralleling)

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

2.0.9.0

2.0.9.0 based on 2.0.8.1

New features

  • Three pump logic routines can now be set up to control the pumping of a substance.
  • Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.
  • All configuration dependent values are now possible to use in the flexible Modbus.

Changes

  • Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350  
  • Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.
  • Added write permission for "Priorities" when the controller is in emulation.
  • EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".  
  • EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.  

Corrections

  • Fixed issue where changes made in the UI were not registered.
  • Fixed issue where the "IO configuration" menu would show empty slots.
  • Fixed issue where tree-structure menu groups could not be collapsed using touch.
  • Fixed issue where iE 250 failed to start up without MIO module.
  • Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".
  • Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.
  • Fixed issue where the display user could not clear DM2 logs.
  • Fixed issue where the iE controller could not start without MIO module. 
  • Fixed issue with missing alarm icons.
  • Fixed issue where the user could enter parameter values outside of valid range.
  • Fixed checksum and counter for VP70.
  • Fixed issue where PIM2.1 DIO levels were inverted.
  • Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms. 
  • Fixed issue where CODESYS user management files were not included in backup/restore.
  • Fixed issue where linked outputs in CODESYS were hidden in IO configuration.
  • Fixed issue where PWM was not working on MIO2.1.

2.0.9.0

04. 05. 2025

2.0.9.0 based on 2.0.8.1

New features

  • Three pump logic routines can now be set up to control the pumping of a substance.
  • Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.
  • All configuration dependent values are now possible to use in the flexible Modbus.

Changes

  • Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350  
  • Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.
  • Added write permission for "Priorities" when the controller is in emulation.
  • EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".  
  • EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.  

Corrections

  • Fixed issue where changes made in the UI were not registered.
  • Fixed issue where the "IO configuration" menu would show empty slots.
  • Fixed issue where tree-structure menu groups could not be collapsed using touch.
  • Fixed issue where iE 250 failed to start up without MIO module.
  • Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".
  • Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.
  • Fixed issue where the display user could not clear DM2 logs.
  • Fixed issue where the iE controller could not start without MIO module. 
  • Fixed issue with missing alarm icons.
  • Fixed issue where the user could enter parameter values outside of valid range.
  • Fixed checksum and counter for VP70.
  • Fixed issue where PIM2.1 DIO levels were inverted.
  • Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms. 
  • Fixed issue where CODESYS user management files were not included in backup/restore.
  • Fixed issue where linked outputs in CODESYS were hidden in IO configuration.
  • Fixed issue where PWM was not working on MIO2.1.

2.0.8.1

10. 02. 2025

Corrections

  • Fixed issue that sometimes prevents start-up of controller.

Changes

  • Improved wire break detection handling.

2.0.8.0

17. 01. 2025

2.0.8.0 based on 2.0.4.1

New features

  • Web Config Tool: Added a Version page with version information of the different software components.
  • Web Config Tool: Added support for PTP time synchronisation.
  • It is now possible to manually disable/enable the USB port  when not in use. (cyber security).
  • EIC: Added Cummins Industrial protocol.
  • EIC: Added Baudouin 6M33 protocol.
  • Added support for DIO2.1 and AIO2.1 plug-in modules.
  • Added device descriptions for 600-series hardware modules for use in CODESYS.
  • Added alarm to indicate unknown traffic on the DEIF network (cyber security).
  • Network port configuration:  New "Standalone" mode to allow CODESYS to be used on Port 0.
  • Added CustomLogic signals to display designer for extra monitoring capabilities.
  • Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.

Changes

  • Improvements to the IP address settings.
  • Logs: It is now possible to press Info when the search filter is highlighted.
  • Introduced an alarm to inform users about malfunctioning hardware modules.
  • Introduced an alarm to inform users about configuration issues on hardware modules.
  • Added fuel level as an engine measurement.
  • Increased the persistent storage to 128KB.
  • Upgraded CODESYS runtime version to v3.5.20.40. 
  • J1939: Added 40 measurements to analogue output functions.
  • Under frequency detection for NEL can now be specified to a tenth of a percentage point.

Corrections

  • Fixed an issue causing DM2 logs to be empty.
  • Fixed an issue causing display texts not to be translated.
  • Fixed an issue that allowed users to change parameters without logging in.
  • Fixed an issue where custom I/O tests were not shown.
  • Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.
  • Web Config Tool: Fixed an issue causing the user management to stay in edit mode.
  • Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.
  • Fixed issues in user management preventing users from being deleted or having reassigned roles.
  • Fixed an issue causing the status LED to go out of sync.
  • Fixed MIO2.1 device description.
  • Fixed issues with voltage measurement when emulating a split-phase system.
  • Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.
  • Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.
  • Fixed an issue in DVC voltage parameters for split-phase.
  • EIC: Fixed an issue cause Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.

2.0.4.1

12. 07. 2024

Initial Release of the iE 250 Marine.

The iE 250 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation. 

The iE 250 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications. 

This software package is intended to serve the CORE level functionality.

Minimum required version of PICUS: 1.0.22.0

New features

  • An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Computer Security Log Management requirements.
  • Updated Volvo EMS2.4 to support ACM module.
  • Added support for CAT C7.1.
  • EIC: Added support for Kohler KDI3404.

Corrections

  • Fixed default value for the regulator status text.
  • Added support for adjusting the brightness level on the controller.
  • Fixed visibility of ECU and CAN parameters.
  • Fixed issue where Custom Logic was missing.
  • Fixed issue where the licence error alarm could occur after a restore from a backup.
  • Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.
  • Fixed issue where disclaimer was incorrectly shown.

 

DEIF 제품을 완전하게 활용하기 위해서는 DEIF에서 제공하는 업데이트를 설치하도록 항상 권장하고 있습니다.

업데이트된 소프트웨어는 언제나 무료로 www.deif.com의 “소프트웨어”에서 “소프트웨어 내려받기”를 통해 내려받기할 수 있습니다.

질문 또는 제품 관련 소프트웨어에 관한 문의는 DEIF A/S +45 96149614 또는 해당 지역의 DEIF 사무소로 연락해 주시기 바랍니다. 그 외에도, support@deif.com로 이메일을 보내 주시면 언제든지 도와드릴 준비가 되어 있습니다.