The MVR-200 series offers integrated or segregated protection with powerful complementary monitoring, measuring, communication and diagnostics information. The MVR-200 is developed using the latest available technologies providing a totally new dimension and options to protection and control engineers.

Versatile Protection Design

MVR-200 series is characterized by fast, versatile and dependable protection functions with uniquely wide operating frequency band of 6…75Hz making MVR-200 perfect choice for the most demanding protection applications including rotating machines.

Modularity

Fully modular hardware construction gives a high level of flexibility; additional I/O or communication cards can be simply plugged in according to application needs.

Usability

Maximum use of the relay is guaranteed by features such as, sophisticated setting aids, highly customizable HMI, file storage of pdf or other supportive documents and extensive user log information. Track down a complete user history register including setting change and other operational history.

Performance

The MVR-200 series offers truly sub-cycle instantaneous triptimes. Powerful PLC programming is included for the most demanding applications allowing for extensive customization. Up to 100 disturbance records of up to 10 seconds each and 10 000 events are stored in non-volatile memory.

Communication

Native Ethernet communication provides for fast and seamless communication. The MVR-200 communicates using variety of standard protocols including IEC 61850 substation communication standard with fast GOOSE messaging.

Savings in Engineering Time

MVR Utility Software free of charge software suite saves valuable engineering time by offering an intuitive and easy to use human machine interface. Download all relay settings instantly using native 100Mb/s Ethernet connection either at relay front port or rear port through Ethernet network.

Standardized Hardware

Trouble free logistics and stocking with highly standardized hardware design. Five CT inputs with software settable secondary currents and software configurable digital input thresholds for voltage are standard features of MVR-200 series.

Variants

MVR-F201

  • Basic range
  • Price performance ratio

MVR-F210

  • Cable and differential protection
  • Low-impedance REF protection
  • Harmonics protection and control
  • 5-shot scheme controlled autorecloser 

MVR-F205

  • Integrated protection, control measurement 
  • Price performance ratio

MVR-F215

  • Double busbar control
  • Directional and voltage protection
  • Cable end differential protection
  • Low-impedance REF protection
  • Harmonics protection and control
  • 5-shot scheme controlled autorecloser
  • Up to class 0.2S power and energy measurement

MVR-F255

  • Large I/O capability
  • Directional and voltage protection
  • Cable end differential protection
  • Low-impedance REF protection
  • Harmonics protection and control
  • 5-shot scheme controlled autorecloser
  • Up to class 0.2S power and energy measurement

MVR-M210

  • 5 time constant accurate thermal model
  • Soft-start protection starting from 6Hz
  • Star-delta started motor supervision
  • 2-speed motor protection

 

  • Three phase overcurrent protection stages INST, DT or IDMT 
  • (Sensitive) Earth-fault protection stages INST, DT or IDMT 
  • Harmonic overcurrent protection / inrush blocking stages INST, DT or IDMT 
  • Cold-load pick-up block 
  • Current unbalance / broken conductor protection stages INST, DT or IDMT 
  • Thermal overload protection (line) 
  • Restricted earth fault protection (low-imp) 
  • Cable-end differential protection 
  • Directional three-phase overcurrent protection stages DT or IDMT 
  • Directional (sensitive) residual overcurrent protection stages DT or IDMT 
  • Intermittent earth fault 
  • Fault locator 
  • Overvoltage protection stages INST, DT or IDMT 
  • Undervoltage protection stages INST, DT or IDMT 
  • Positive sequence under/overvoltage protection stages INST, DT or IDMT 
  • Residual voltage protection stages INST, DT or IDMT 
  • Frequency protection stages 
  • Rate of change of frequency 
  • Vector Jump / surge 
  • Reverse/under/over power protection stages INST, DT or IDMT 
  • Synchrocheck  
  • Auto-reclose 
  • Fuse failure 
  • Current transformer supervision 
  • Switch onto fault logic 
  • Breaker failure protection 
  • Programmable stage

자료

Approvals/Certifications
언어 자료 개정
Flag eng DoC_4910290116_UK.pdf A
Data Sheet
Designer's Handbook
Installation Instructions
Operator's Manual

소프트웨어, 문서 또는 백서를 찾고 계십니까?

DEIF는 수십 년간 독창적인 상표를 통해 소프트웨어 업데이트에 대한 무제한 무료 접근, 기술적으로 상세한 제품 설명서 및 미래의 산업 관련 주제에 대한 교육적이고 고무적인 백서를 제공합니다.